c) API: canplus_Open:
Type in „y‟ and <ENTER>, It will run the canplus_Open API and return the USB handle
number operating with the device. At this point CAN Open command is executed with the
Supplied CAN bit rates, time stamp flags. So the Green LED on the device will be solid
“green”. In the demo code the time stamp is turned ON, and CAN bit rate is 1 mbps.
d) API: canplus_Write:
At this point the demo code get into testing canplus_Write API. First Standard frame will be
transmitted with ID : 123, 8 bytes data, Data: A1B2C3D4E5F61234
Type „y‟ and <ENTER>
Then you can monitor the standard CAN frame transmitted on CAN network.