4.1.9 Echo / Synchronize (E)
Summary
Clear transmit data buffers. Data buffers should be cleared immediately after opening the CAN
channel to prevent erroneous as a result of sending old data in the buffer.
Definition
E<CR>
Parameters
None
Remarks
Example:
E<CR>
Clear data buffers.
Return Codes
E<CR> = OK
<BELL> = ERROR